Resources & Technical Support for Airless SCR Systems

Looking for maintenance data, emissions compliance benchmarks, or integration specs for your project? Explore our support hub for detailed answers and downloadable content. The E.I. Williams/IMS airless SCR platform streamlines everything—from Tier 4 compliance to long-term service planning.

Frequently Asked Questions

Compressor-free DEF dosing system
Modular design with built-in generator exhaust silencer
95% of components prewired and pretested before delivery

Minimal. Without air compressors or pneumatic systems, maintenance is simplified. See below for the full 5-year SCR service schedule.

Yes, the system supports passive and active DPF + SCR integration for full aftertreatment compliance.

Yes, this would be a possibility once an authorized remote technician is trained by us.

5-Year SCR Maintenance Schedule

Task
Frequency
Time per engine
Sensor signal validation (via ECU)
Yearly
5 min
Cable & connector inspection
Yearly
10 min
Urea leak / hose damage check
Yearly
10 min
Urea filter replacement
Every 2 yrs
10 min
SCR pressure differential check
Yearly
15 min
Sensor & inlet nut cleaning
Every 2 yrs
20 min
Urea pressure sensor replacement
As needed
20 min
Injector replacement
Year 3 & 5
30 min
Exhaust sensor + hose replacement
Year 3 & 5
1 hour
NOx sensor replacement
Year 3 & 5
30 min
Temperature sensor replacement
Year 3 & 5
30 min
Urea pump replacement
Year 5
1 hour
Urea level sensor replacement
Year 5
1 hour
Hoses, connectors, valves
Year 5
8 hours

Tier 4 Final Emissions Data

Category

Generator sets

NOx (g/kWh)

0.67 (0.50)

PM (g/kWh)

0.03 (0.022)

CO (g/kWh)

3.5 (2.6)

HC (g/kWh)

0.19 (0.14)

Category

NOx (g/kWh)

PM (g/kWh)

Generator
sets

0.67 (0.50)

0.03 (0.022)

Category

CO (g/kWh)

HC (g/kWh)

Generator
sets

3.5 (2.6)

0.19 (0.14)

Values shown meet or exceed EPA Tier 4 Final emissions limits.

Emergency Shutdown Safeguards

The airless DEF injection system includes a water cooling loop that protects the injector tip during unplanned high-load shutdowns — even without DEF flow.

Whitepapers & Downloads

Featured Publications

Need engineering specs or Tier 4F compliance documentation?

We’ll provide the full technical package — datasheets, CAD drawings, and emissions curves — for your project.